Metal Building Certifications: Wind Ratings, Snow Loads & Engineered Drawings
Metal building certifications help determine whether a structure is designed to meet specific wind and snow load requirements. These requirements can vary depending on the building’s location, size, intended use, and local building codes.
When purchasing a metal carport, garage, RV cover, workshop, or larger commercial building, understanding certification options can help you choose a structure that meets your project’s requirements.
At Legacy Carports, we offer several wind and snow load certification packages, along with engineering documentation options such as generic drawings, modified engineered drawings, and site-specific plans.
Quick Answer: What Metal Building Certifications Are Available?
Legacy Carports offers several common wind and snow load certification combinations, including 25 PSF / 120 MPH, 35 PSF / 145 MPH, and 65 PSF / 115 MPH.
These ratings represent different combinations of snow load and wind resistance. The appropriate certification depends on the structure’s location, building design, manufacturer, and applicable requirements.
We also offer engineering documentation options, including generic engineered drawings, modified engineered wet-sealed drawings, and site-specific drawings.
Not every project requires the same certification or engineering documents. Customers should confirm their local building department’s requirements before finalizing the building design.
On This Page
What Is a Certified Metal Building?
A certified metal building is a structure engineered to meet specified design requirements, such as wind and snow loads.
Certification helps establish the conditions the building has been designed to withstand when constructed and installed according to its approved specifications.
A building’s certification may influence its framing, bracing, truss design, anchoring, doors, openings, and foundation requirements.
It is important to understand that certification does not mean a building is approved for every location. The structure must still meet the requirements applicable to its installation site.
Understanding Wind Load Certifications
Wind load certification refers to the wind conditions a metal building is engineered to resist.
Wind ratings are commonly expressed in miles per hour (MPH). For example, a building may be designed for a specified wind speed of 120 MPH or 145 MPH, depending on its certification package.
However, wind design involves more than speed alone. Building height, surrounding terrain, wind exposure, enclosure, structural design, and local building requirements can all influence the forces acting on a structure.
A building installed in an open field may experience different wind conditions than a similar building surrounded by other structures.
This is why the appropriate wind certification should be determined using the building’s location and applicable engineering requirements.
Understanding Snow Load Certifications
Snow load certification refers to the weight of snow a structure is engineered to support under specified design conditions.
Snow loads are commonly expressed in pounds per square foot (PSF).
For example, a 35 PSF rating represents a design load of 35 pounds per square foot under the conditions specified by the engineering documentation.
Higher snow load requirements are often associated with colder climates, mountainous regions, or locations that experience significant snowfall.
Snow load design can affect the building’s frame, trusses, roof system, spacing, and bracing.
An important distinction is that ground snow load and roof snow load are not always the same. The required design depends on the applicable code, roof configuration, and engineering criteria.
Common Metal Building Certification Options
Legacy Carports offers several common certification combinations for qualifying structures.
Snow Load Rating | Wind Rating | Certification Package |
|---|---|---|
25 PSF | 120 MPH | 25 PSF / 120 MPH |
35 PSF | 145 MPH | 35 PSF / 145 MPH |
65 PSF | 115 MPH | 65 PSF / 115 MPH |
These packages provide different combinations of wind and snow load resistance.
The 35 PSF / 145 MPH package provides a higher listed wind rating than the other examples, while the 65 PSF / 115 MPH package provides the highest listed snow load rating.
These are available certification combinations, not a ranking of which structure is strongest overall. The appropriate package depends on local requirements, the building’s design, and the engineering criteria used.
Availability may vary by manufacturer, region, structure size, and project specifications.
How Certifications Affect Metal Building Framing
Certification requirements can influence how a metal building is constructed.
For tubular steel buildings, higher structural demands may require changes to the steel framing, truss system, frame spacing, bracing, or anchoring.
For example, certain structures may require additional bows, closer frame spacing, heavier framing components, or upgraded support systems to meet the required design loads.
Red iron and structural steel buildings are typically engineered around the individual project’s specifications, allowing the structural design to account for the required wind and snow loads.
These requirements should be considered before manufacturing begins because structural changes may affect the design, engineering documents, and final price.
What Are Engineered Metal Building Drawings?
Engineered drawings document important structural details of a metal building.
Depending on the drawing package, these documents may include framing details, building dimensions, structural connections, anchoring requirements, design loads, and other engineering information.
Engineered drawings are often requested during the permitting process so the local building department can review whether the proposed structure meets applicable requirements.
The type of drawings required depends on the project and the building department reviewing the plans.
Generic Engineered Drawings
Generic engineered drawings are commonly used for standard metal building designs that fall within a manufacturer’s established engineering specifications.
These drawings cover predetermined design conditions and structural configurations rather than being created specifically for one customer’s property.
Generic drawings may be sufficient for some permitting offices when the proposed building meets the conditions covered by the engineering package.
However, not every jurisdiction accepts generic drawings. Some building departments require additional documentation, modifications, or drawings specific to the installation site.
Customers should verify which documents their permitting office requires before ordering additional engineering services.
Modified Engineered Wet-Sealed Drawings
Modified engineered drawings may be needed when a building includes design changes or features that fall outside the manufacturer’s standard engineering package.
For example, a project may require additional engineering review because of unusually large openings, modified wall sections, custom frame-outs, or other structural changes.
A wet-sealed drawing generally refers to engineering documentation carrying an engineer’s original physical seal and signature, where that format is required or provided.
Depending on the manufacturer and jurisdiction, signed and sealed documents may also be available electronically.
Modified engineered drawings may involve additional engineering fees and processing time because the revised design must be reviewed and approved.
It is important to identify these requirements early so the appropriate documents can be prepared before permitting or manufacturing.
Site-Specific Engineered Drawings
Site-specific engineered drawings are prepared around the requirements of a particular building project or installation location.
Unlike generic drawings, site-specific engineering considers the applicable project conditions and design requirements.
These may include the building’s location, dimensions, wind and snow load criteria, structural configuration, and other information requested by the building department.
Some permitting offices require site-specific engineering even when a manufacturer offers standard certified structures.
Depending on the project, separate foundation engineering, site plans, or additional documentation may also be necessary.
Site-specific drawings may require additional fees and preparation time, so customers should confirm these requirements before finalizing their order.
Generic vs. Modified vs. Site-Specific Drawings
Understanding the difference between drawing types can help customers avoid ordering unnecessary documents or submitting the wrong information during permitting.
Drawing Type | Common Purpose | What to Know |
|---|---|---|
Generic Engineered Drawings | Standard building designs | Based on predetermined engineering conditions |
Modified Engineered Drawings | Changes to standard structural designs | May require additional review, calculations, or a professional seal |
Site-Specific Drawings | Individual projects or locations | Prepared around applicable site and project requirements |
A modified drawing and a site-specific drawing are not necessarily interchangeable. The documents required depend on what is being changed, what the manufacturer can provide, and what the local building department requests.
Do Metal Buildings Require Permits?
Permit requirements vary by state, county, city, and local jurisdiction.
Some areas may require building permits for most permanent metal structures, while others may have different rules depending on the building’s size, use, foundation, or location.
When a permit is required, the building department may ask for engineered drawings, site plans, foundation information, wind and snow load ratings, or other supporting documents.
At Legacy Carports, customers are responsible for confirming and obtaining the permits required for their projects.
We recommend contacting your local building department before finalizing your design to determine which certification and engineering documents will be needed.
Does a Certified Metal Building Automatically Meet Local Building Codes?
Not necessarily.
A building may carry a particular wind and snow load certification but still require additional documentation or design changes to satisfy the local building department.
For example, the required wind exposure category, foundation, anchoring method, or structural configuration may differ from the assumptions used in a standard engineering package.
The selected building certification must match the applicable design requirements, and the completed installation must follow the approved specifications.
Final permit approval is determined by the appropriate local authority.
How Certifications and Engineering Affect Price
Certification and engineering requirements can affect the final cost of a metal building.
A structure requiring additional framing, stronger trusses, closer frame spacing, upgraded anchoring, or other structural modifications may cost more than a standard configuration.
Engineering documentation can also affect price. Generic drawings may be included with qualifying structures, while modified drawings, wet-sealed documents, and site-specific engineering may involve additional fees.
These costs depend on the manufacturer, building design, installation location, and documentation requirements.
Reviewing certification and permitting needs early can help customers understand potential costs before placing their order.
Why Planning Certification and Engineering Early Matters
Certification requirements should be reviewed before the building design is finalized.
A customer may initially select a structure based on appearance, size, or price, only to discover that the local building department requires a different wind rating, snow load, or engineering package.
These changes can affect framing, anchoring, building dimensions, pricing, and manufacturing.
Confirming the requirements early helps reduce the chance of delays and makes it easier to select a structure that meets the project’s needs.
Related Metal Building Options
Framing Options
Wind and snow load requirements can affect framing gauge, truss design, frame spacing, bracing, and other structural components.
Foundation & Anchoring Options
Certified structures may require specific anchoring methods or foundation details to meet their engineered design requirements.
Roof Options
Roof style, pitch, and framing can influence how a structure is engineered for environmental loads.
Garage Door Options
Garage door size, placement, and certification can affect structural openings and wind resistance requirements.
Wind & Snow Load Resources
Learn more about wind and snow load requirements and how they may apply to your installation location.
Related Building Options
Certification is just one part of your building. Explore our other building options to see how each choice comes together to create a metal building that fits your property and how you plan to use it.
Get Help Understanding Metal Building Certifications
Choosing the right metal building certification begins with understanding the installation location, building design, and local requirements.
Legacy Carports can help customers review available wind and snow load certification packages, generic engineered drawings, modified drawings, and site-specific engineering options.
Whether you are planning a carport, garage, RV cover, workshop, or commercial building, reviewing these requirements early can help make the ordering and installation process smoother.
Ready to start planning your structure? Use our 3D Builder or reach out to Legacy Carports for help understanding the certification and engineering options available for your project.